Markerless motion capture for running: validity and reliability of whole-body, joint, and muscle kinematics.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 41418503.
- Also identified by DOI 10.1016/j.jbiomech.2025.113133.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Markerless motion capture can greatly enhance the accessibility and efficiency of running-kinematics analysis. In this study we aimed to establish the validity and reliability of a markerless motion-capture system (OpenCap) for measuring kinematics of the whole body, individual joints, and lower-limb muscle-tendon units, during running at various speeds. Markerless and marker-based motion-capture results were compared for 30 runners running on a treadmill at five speeds (8-16 km/hr). OpenCap demonstrated similar validity for joint angle measurements compared to other markerless systems that have previously been compared to marker-based motion capture. However, we found systematic differences between OpenCap and marker-based motion capture throughout the stride cycle, and across running speeds and kinematic variables. Between-system disagreements were most evident around peak centre-of-mass displacements and joint angles, and during the swing phase, with smaller differences observed at touchdown, take-off, and during the stance phase. We thus recommend caution when quantitatively comparing kinematic outcomes from OpenCap to other motion-capture systems. Despite these differences, high agreement in inter-stride and inter-trial variability was observed between systems across all kinematic variables. Overall, OpenCap is a powerful tool to enable accessible, efficient, and reliable 3D measurements of whole-body, joint, and muscle-tendon unit kinematics during running.
Medical subject headings
- Running
- Muscle, Skeletal
- Joints