Proximal Implant Breakage after Cephalomedullary Nailing of Extra-capsular Proximal Femur Fractures: A Multi-Center Retrospective Comparative Analysis.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 41493187.
- Also identified by DOI 10.1097/BOT.0000000000003143.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare rates of nail breakage of three common cephalomedullary nails (CMNs) for the treatment of AO/OTA 31A1-3 femur fractures. Design: multi-center retrospective study. 13 Level I trauma centers. Adult patients with AO/OTA 31A1-3 femur fractures treated between 2014 and 2021with the Trochanteric Fixation Nail-Advanced (TFNA), Gamma3, or Trigen InterTAN were included. The primary outcome was implant (nail or head element) breakage. The secondary outcomes included nonunion, cut-out/cut-through and overall reoperation rate. Univariate and multivariable analyses were performed to compare breakage rates between implants while controlling for age, sex, AO/OTA 31A1-2 vs 31A3 fracture patterns, low vs high-energy mechanisms and post-operative neck shaft angle (NSA). 2,130 patients were included: 770 (36.2%) TFNA, 1,073 (50.4%) Gamma3 and 287 (13.5%) InterTAN. The InterTAN group had younger patients (median age: InterTan: 74, TFNA: 77, Gamma3: 80, p<0.001), more high-energy mechanisms (InterTan: 23%, TFNA: 14%, Gamma3: 10%, p=0.001), and more varus malreductions (NSA<128.5: InterTan: 46%, Gamma3: 39%, TFNA: 34%, p=0.001). The TFNA group was more likely to have an AO/OTA 31A3 fracture pattern than the Gamma3 (TFNA: 17.3%, InterTAN: 14.3%, Gamma3: 12.1%, p=0.002). The overall rate of implant breakage was 1.4% in the InterTAN group, 1.2% in the TFNA group, and 0% in the Gamma3 group. All breakages occurred in the presence of a nonunion or delayed union. Only two of the 31A3 fracture patterns resulted in breakage, both in the TFNA group, while the remainder occurred in 31A1-2 fracture patterns (p = 1.0). After controlling for confounding factors listed above, the TFNA and InterTAN groups were associated with a marginally increased odds of implant breakage compared to the Gamma3 (TFNA vs Gamma3: OR 0.04, 95% CI <0.01-0.5, p=0.034; InterTAN vs Gamma3: OR 0.04, 95% CI <0.01-0.5, p=0.037), while there was no difference between the TFNA and InterTAN (p=0.991). Post-operative neck shaft angle was not independently predictive of breakage (p = 0.55). This study suggests that the TFNA may be slightly more prone to breakage than the Gamma3 when used for extracapsular proximal femur fractures. However, breakage is a rare event after cephalomedullary nailing with all implants evaluated, is always associated with nonunion or delayed union, and the magnitude of this difference may not be clinically relevant. III.
Anatomy
- femur