A wearable 3D-printed hollow microneedle device for pressure-driven interstitial fluid collection and testing.

Hacıosmanoğlu, Nedim; Ece, Emre; Inci, Fatih · Lab Chip · 2026

basic_science · Level V

Where this comes from

Abstract

Interstitial fluid (ISF) is the extracellular fluid within the dermis that transports biomolecules diffusing from blood vessels to lymphatic vessels. Owing to its blood-like composition and accessibility only a few millimeters beneath the skin surface, ISF has recently attracted considerable attention as a minimally invasive reservoir for biomarker analysis. Conventional ISF collection relies on invasive sampling methods. Microneedle (MN) technology has emerged as a promising approach for developing minimally invasive ISF sampling and analysis systems. We present a design and one-step stereolithography (SLA)-based 3D printing fabrication of a wearable hollow MN device: μHolloSense. The device is capable of negative pressure-assisted ISF collection <i>via</i> its syringe port and is compatible with lateral flow assay (LFA) testing through a dedicated test port. The overall cost was ∼$1 per single-use device, including all components, and $1.50 per SARS-CoV-2 antigen test, used here as a proof-of-concept LFA system. Additionally, a 3D-printed, agarose-based skin-mimicking platform was developed to provide a standardized tool for evaluating MN sampling performance. Beyond this model system, <i>ex vivo</i> skin experiments were conducted to validate the applicability of μHolloSense for ISF collection in biologically relevant tissues. Our results demonstrate that μHolloSense, featuring a refined tip diameter (44.19 ± 2.4 μm) and height (1207.93 ± 11.25 μm), is capable of drawing liquids at a rate sufficient to reach the dermis, exhibiting robust mechanical properties (>0.17 N compressive force per needle) in IgG LFA tests across antigen concentrations of 1, 10, 100, and 250 pg mL<sup>-1</sup>. <i>Ex vivo</i> experiments on mice skin confirmed ISF extraction of up to 6 μL per sampling, with protein concentrations consistent with physiological levels. Collectively, this work presents a unified strategy for the design, fabrication, and evaluation of 3D-printed hollow MN systems with an integrated negative-pressure approach for ISF-based biomolecule analysis. In the future, further optimization and clinical validation of this platform would enable continuous, minimally invasive monitoring of a wide range of biomarkers, paving the way for point-of-care diagnostic and personalized health applications.

Medical subject headings