Magnetoencephalography changes in cervical spondylotic myelopathy: a study of resting-state and somatosensory evoked magnetic fields.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 41689592.
- Also identified by DOI 10.1007/s00586-026-09773-9.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study aimed to assess the diagnostic utility of optically pumped magnetometer-based magnetoencephalography (OPM-MEG) in patients with cervical spondylotic myelopathy (CSM). A total of 31 CSM patients and 32 healthy volunteers were enrolled. Somatosensory-evoked magnetic fields (SEFs) were recorded using OPM-MEG. Clinical evaluations included the Japanese Orthopaedic Association (JOA) scale and the Short Form-36 (SF-36) health survey. Diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis. Compared with healthy controls, CSM patients demonstrated decreased α power in the occipital region, and increased γ power in the occipital, temporal, and frontal regions. Significant differences in phase locking value (PLV) were observed in the α band between the occipital-frontal regions. The latency of the maximum SEF was 49.66 ± 5.51 ms in healthy controls and 58.63 ± 7.73 ms in CSM patients. ROC analysis for SEF latency yielded an area under the curve of 0.844, with a cutoff value of 55.0 ms, sensitivity of 77.4%, and specificity of 81.3%. MEG may a helpful tool in the functional assessment of the neurological deficits in CSM, and shows potential as an useful method for clinical diagnosis and functional evaluation of this condition.
Anatomy
- cervical spine