Performance of the 12-lead ECG in predicting short- and long-term risk of sudden cardiac death.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 41787030.
- Also identified by DOI 10.1038/s41746-026-02456-1 and PMC identifier 13079725.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
We evaluated the performance of 12-channel ECG in predicting sudden cardiac death across different time intervals using a retrospective data set of 17,625 high-risk cardiac patients who underwent coronary angiography (2007-2018) with follow-up data until 2022. Extreme gradient boosting using 12SL Marquette software-derived parameters from digital ECG recording was used to train and validate models using a random 80/20 split. Model performance was evaluated in both unbalanced and risk-factor-balanced case-control sets. Using single ECG, both long-term (from baseline ECG) and short-term predictions (from the last recorded ECG) achieved a modest area under the curve (AUC) of 0.68 in the unbalanced validation and 0.59/0.63 in the balanced validation (long-/short-term). Adding clinical risk factor data resulted in AUC 0.70/0.71 (unbalanced) and 0.64/0.62 (balanced) for long- and short-term prediction. Adding data of observed ECG changes during follow-up for short-term prediction resulted in the best model performance (0.72/0.66; unbalanced/balanced).