A personalized iodine delivery rate-based injection protocol in coronary angiography on photon-counting CT.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 41792575.
- Also identified by DOI 10.1007/s00330-026-12413-x.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To propose and validate a personalized iodine delivery rate (IDR) based injection protocol for coronary CT angiography (cCTA) on photon-counting CT. First, ideal IDR (IDR<sub>IDEAL</sub>) was retrospectively calculated for a HU target of 500 in 55 keV image reconstructions. Next, linear regression analysis was performed with IDR<sub>IDEAL</sub> and demographic parameters to derive a candidate IDR formula. This was implemented in two validation groups characterized by injection rate (3.5 and 5.0 mL/s). Here, coronary enhancement was quantified and equivalence assessed for a predefined HU range (500 ± 50). Additionally, a reader study assessed perceived enhancement of the coronary tree. This IRB-approved study used a retrospective cohort of 162 patients (group A: 58 ± 12 years; 81 men) and two prospective cohorts of 51 patients (group B1: 60 ± 13 years; 22 men and group B2: 59 ± 12 years; 30 men). IDR<sub>IDEAL</sub> correlated best with fat-free mass (FFM) (r = 0.67) and was integrated for contrast personalization. Prospectively, mean coronary enhancement was 533 ± 97 HU and 528 ± 68 HU for both groups (p = 0.79) with mean IDR values of 1.01 ± 0.11 gI/s and 1.07 ± 0.14 gI/s. However, distribution variances were significantly different (p = 0.015). Subjective scoring showed no differences between the two groups on overall and per-vessel level (p > 0.05). A personalized, IDR-based injection protocol for cCTA was proposed and validated. FFM was best for IDR<sub>IDEAL</sub> prediction. Higher injection rates provided more precise coronary enhancement. Question Virtual mono-energetic images lead to low iodine delivery rate settings, but the impact on coronary enhancement is not clear. Findings An iodine delivery rate-based injection protocol implementing personalized contrast volume dilutions with set injection duration and high injection rate improved coronary enhancement. Clinical relevance Iodine delivery rate fine-tuning is a promising approach for coronary CT angiography with low iodine volumes. High injection rates provide more accurate and precise coronary enhancement.