Comment on "Identifying high glucose variability using non-glycemic factors in low continuous glucose monitoring use settings".
editorial · Level V
Where this comes from
- Record sourced from PubMed, PMID 41850951.
- Also identified by DOI 10.1016/j.pcd.2026.03.003.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This Letter to the Editor critically evaluates the non-CGM-related clinical indicators of glycemic variability (%CV ≥36%) in type 2 diabetes patients reported by Chandran et al., given the low utilization rate of continuous glucose monitoring (CGM) systems. It points out several inconsistencies in definitions and numerical values (including the coefficient of variation calculation formula, summary metrics, confidence intervals, and chart interpretation). Furthermore, clarifying the model specifications and reporting methods would improve the reproducibility of the study and facilitate its application in developing CGM-prioritized treatment strategies.