Generation of Fibrin-Based Aortic Vessels with Layer-Specific Cell Architecture Under Pulsatile Perfusion in a Clinical Organ Care System.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 41894125.
- Also identified by DOI 10.1007/s10439-026-04087-9.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Overcoming the limitations of synthetic vascular grafts in the development of biocompatible and regenerative vessels remains a long-term objective in tissue engineering. In this study, we engineered large-diameter fibrin-based vascular grafts with a target inner diameter of 21 mm replicating all three layers of the native human vessel wall in vitro. The Tunica media was reconstructed using a compressed high-density (25 mg/mL) fibrin matrix seeded with smooth muscle cells expressing α-SMA and calponin, differentiated from adipose-derived mesenchymal stem cells (ASCs). The Adventitia-equivalent was formed in a 5 mg/mL fibrin gel containing ASCs, human umbilical vein endothelial cells (HUVECs), and normal human dermal fibroblasts (NHDFs) to enable the formation of a capillary-like network resembling the native adventitial Vasa vasorum. The luminal surface was endothelialized with HUVECs to replicate the Tunica intima. While controls were cultured statically for 7 days, other grafts were evaluated under pulsatile perfusion at physiological pressures using the TransMedics<sup>®</sup> "Organ Care System Heart<sup>™</sup>". The stepwise fabrication technique resulted in three-layered bioartificial vessel equivalents with a mean inner diameter of 21 mm. All constructed vessels (n = 3) maintained sufficient biomechanical stability to withstand physiological pressure (120.9 ± 1.2 to 61.4 ± 12.5 mmHg) at 60 bpm throughout the perfusion period. The aortic grafts exhibited a cyclic stretch (8.95 ± 2.03%) within the physiological range of native vessels. Mechanical stimulation induced a layer-specific physiological cell morphology and alignment across all three layers of the vascular wall. Endothelial coverage was high on static grafts (81.39 ± 2.37%) and on one of three dynamic grafts. Shear stress during perfusion (0.38 ± 0.03 dyn cm<sup>-2</sup>) remained below physiological levels, and further evaluation under prolonged perfusion (> 21 days) is required to assess long-term biomechanical stability and vascular functionality. This approach may be considered a proof of concept and constitutes a first step toward the development of biometric and functional large-diameter vessel replacements.