Custom Distal Humeral Replacement with Locked Flange in Revision Total Elbow Arthroplasty.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 41903673.
- Also identified by DOI 10.1016/j.jse.2026.03.015.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Revision total elbow arthroplasty (rTEA) is increasing as the number of primary TEA increases. In a revision setting, surgeons often face the challenge of distal humeral bone loss. Techniques described include large segment allografts, allograft prosthetic composites (APC) and megaprosthesis. Within the literature there is limited evidence on the use of megaprosthesis in a revision TEA setting for non-tumour indications. We present our institutions experience of managing significant distal humeral bone loss in this context using a novel custom uncemented distal humeral replacement with a locked flange. Patients were identified using a tertiary centres local joint registry alongside electronic patient records. Variables collected included: patient demographics, indication, number of previous surgeries, range of movement, complications, Oxford Elbow Score, Pain, EQ5D and SANE scores. ResultsThe cohort comprised 11 custom distal humeral replacements. The mean age was 66 years (Range 47-79). Mean follow up was 32 months (range 6-93). The mean number of prior procedures was 6. Indications for the rTEA were 4 for aseptic loosening, 5 for infection, 1 for failed fracture fixation, and 1 peri-prosthetic fracture. The cohort demonstrated improvements in their range of movement as well as mean Oxford elbow score, SANE, EQ5D and pain score. Two patients have since required further surgery, one due to implant dissociation and one due to recurrent deep infection. Bone loss in the distal humerus can provide a complex challenge in the revision setting. The use of custom megaprosthesis has evolved due to challenges associated with alternative strategies. However, there is limited data in the literature regarding outcomes in a non-tumour setting. We report good early to mid-term clinical and radiographic outcomes of a custom uncemented distal humeral replacement with a locked flange design, and a lower complication rate compared to alternative surgical techniques reported in the literature. Level IV, Case Series, Treatment Study; Key Words: Custom implant, Revision Elbow Arthroplasty, Total Elbow Arthroplasty, Megaprosthesis.
Anatomy
- humerus
- elbow