Risk-Guided Atrial Fibrillation Screening With Artificial Intelligence-Enabled Electrocardiogram Models: A VITAL-AF Trial Analysis.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 41983618.
- Also identified by DOI 10.1016/j.jacc.2026.01.087.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Screening for atrial fibrillation (AF) may lead to earlier detection and initiation of preventive measures. Current AF screening approaches using a guideline age-based threshold of ≥65 years have shown limited yield. In an AF screening trial, we assessed whether the screening effect was larger among individuals at elevated AF risk using validated clinical and electrocardiogram (ECG)-based artificial intelligence (AI) risk models. VITAL-AF was a cluster-randomized trial of patients aged ≥65 years treated at 1 of 16 primary care practices affiliated with Massachusetts General Hospital. Patients randomized to a screening practice were screened using a single-lead ECG. Among VITAL-AF participants without prevalent AF with at least one 12-lead ECG within 3 years before enrollment, we estimated AF risk using 3 validated models derived outside of VITAL-AF: the Cohorts of Heart and Aging Research in Genomic Epidemiology-AF (CHARGE-AF) clinical score, an AI-based model using a 12-lead ECG alone (ECG-AI), and a model combining ECG-AI and CHARGE-AF (CH-AI). Two-year incident AF discrimination was assessed by the time-dependent area under the receiver-operating characteristic curve (AUROC) and average precision. AF screening effect was defined as the difference in 2-year incident AF diagnosis rate (per 100 person-years) in screening vs control across AF risk deciles. Of 30,630 VITAL-AF participants without prevalent AF, 16,937 had pretrial ECG and clinical data. Each score discriminated 2-year AF risk according to AUROC (CHARGE-AF: 0.711 [95% CI: 0.671-0.749]; ECG-AI: 0.784 [95% CI: 0.743-0.819]; CH-AI: 0.788 [95% CI: 0.754-0.824]) and average precision (0.0952 [95% CI: 0.0836-0.112]; 0.132 [95% CI: 0.113-0.157]; 0.133 [95% CI: 0.117-0.159]). An AF screening effect was observed in the top decile of CH-AI (AF diagnosis rate in screening 10.07/100 person-years [95% 8.28-11.87] vs 7.76 [95% 6.30-9.21] in control, P < 0.05), corresponding to a difference in AF diagnosis rate of 2.32/100 person-years (95% CI: 0.01-4.63) and number-needed-to-screen of 43 per year. Use of ECG-based AI and clinical factors identified individuals at particularly high risk for AF who may benefit from screening. Findings suggest a trade-off between increasing AF screening efficiency and decreasing population coverage (ie, restriction of the screening pool). Future studies are needed to determine whether a risk-based approach is optimal or whether consideration of additional clinical- and systems-level factors (eg, access, health care system engagement) can further refine AF screening strategies. (Screening for Atrial Fibrillation Among Older Patients in Primary Care Clinics [VITAL-AF]; NCT03515057).
Medical subject headings
- Atrial Fibrillation
- Electrocardiography
- Artificial Intelligence
- Mass Screening