Usefulness of lung sound data collection using Skeeper SM-300® device: A pilot study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 42127014.
- Also identified by DOI 10.1371/journal.pone.0348588 and PMC identifier 13170829.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Digital stethoscope has been introduced to clinical practice and are developing in many aspects. Overwhelming pandemic requires non-contact healthcare support, and recent growth of artificial intelligence necessitates high-quality data collection. We studied the usefulness of a novel, remotely applicable device Skeeper SM-300®. A single center, prospective, single-arm, investigator-blinded investigation was conducted. Sixty-four participants (normal individuals, stable/exacerbated COPD, stable/exacerbated bronchial asthma, pneumonia, ILD, and pleural effusion) had their lung sounds examined with a conventional stethoscope, while simultaneously recorded using the device, and classified into normal, crackle, wheezing and decreased sound. Three specialists (Raters) listened to the digitally recorded lung sounds and classified them. Non-inferiority of Skeeper SM-300® compared with conventional stethoscopy was examined. Audible acceptability of tidal breathing sounds compared with deep breathing sound, examinees' comfort with the new device, acceptability of digital lung sounds, and diagnostic accuracy after listening to the recorded lung sounds were also evaluated. Among four breathing sounds, wheezing had the highest percentage of correct answers. Three Raters' judgment of classifying electronic lung sounds showed consistent agreement with the conventional stethoscopic result. demonstrating statistically significant agreement between the conventional and electronic stethoscopy (к = 0.8337, к = 0.8158, and к = 0.8043, respectively). Audible acceptability of tidal breathing sounds resulted in fair agreement, with a к-value ranging from 0.5 to 0.8. A majority of patients expressed that they were fairly comfortable with being examined with the device. Diagnostic accuracy on listening to "deep breath" showed a nearly perfect agreement. We verified that the novel electronic stethoscope showed high credibility, yielded highly accurate results, and exhibited non-inferiority compared with conventional stethoscopy. Our investigation supports the usefulness of this novel digital auscultatory device as a credible substitute for conventional analogue stethoscopy.
Medical subject headings
- Respiratory Sounds
- Stethoscopes
- Auscultation
- Data Collection
- Lung