Near-infrared fluorescence imaging-guided surgery using cRGD-ZW800 to improve surgical resection margins in oral cancer: a phase I/II feasibility trial.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 42173866.
- Also identified by DOI 10.1038/s41467-026-73554-7.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In oral squamous cell carcinoma (OSCC) surgery, inadequate tumor margins are reported in up to 85% of cases, adversely affecting outcomes. In this prospective, single-center study (n = 31; NCT04191460), we evaluated the safety and imaging feasibility of cRGD-ZW800-1, a near-infrared fluorescent integrin-targeted tracer. The secondary objective was to determine whether intraoperative fluorescence imaging could identify inadequate resection margins and inform surgical decision-making. Patients received 0.01, 0.025, or 0.05 mg/kg cRGD-ZW800-1, and tracer uptake was quantified using in vivo multi-diameter single-fiber reflectance and single-fiber fluorescence spectroscopy to optimize dosing and timing. All doses were well tolerated, achieving tumor-to-background ratios exceeding 4.5, with optimal performance at 0.025 mg/kg. Fluorescence imaging detected all 23 inadequate margins, including nine undetected by conventional assessment (sensitivity 100% versus 70%), altered surgical plans in five cases, and avoided adjuvant radiotherapy in three cases. These findings demonstrate that cRGD-ZW800-1 is safe, tumor-specific, and facilitates intraoperative margin assessment in OSCC.