Impact of Distance from The Isocenter on Local Control and Toxicity for Zero Margin, Single-Isocenter Multi-Target VMAT based Stereotactic Radiosurgery for Brain Metastases.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 42235693.
- Also identified by DOI 10.1016/j.ijrobp.2026.05.031.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Radiosurgical treatment of multiple intracranial targets using a single isocenter is more efficient than sequential isocenter treatment. The primary concern with single-isocenter, multitarget (SIMT) stereotactic radiosurgery (SRS) is that rotational error may cause underdosing of peripheral lesions and/or increased normal tissue toxicity, particularly for targets distant from the isocenter. Many centers mitigate this risk by adding a planning target volume (PTV) margin, which increases dose to normal brain tissue. This study examined whether distance from the isocenter affects local tumor control or toxicity in patients treated with SIMT SRS using a 0 mm PTV margin. We retrospectively evaluated 429 patients with 3,039 intracranial tumors treated with SIMT SRS or fractionated SRS (fSRS) using single-isocenter volumetric modulated arc therapy (VMAT) plans with a 0 mm CTV/PTV expansion from GTV. All treatments used a Varian HD-120 MLC on a 6-degree-of-freedom couch. Local failure was defined as ≥25% increase in maximum tumor diameter (minimum 3 mm) or viable tumor cells at salvage surgery. Toxicity was defined as CTCAE v5.0 CNS grade ≥3. Of the 3039 tumors evaluated, 1510 and 1034 tumors had clinical and radiographic follow-up at 6-months and 1-year, respectively. Median distance from the isocenter was 4.9 cm (range 0.04 - 13.4 cm) and 70% of tumors in this study were ≥4 cm from the isocenter. 1-year local control was 95.1% (95% CI 94.0 - 96.1) and freedom from grade ≥3 toxicity was 98.4% (95% CI 97.8 - 99.0). Larger tumor volume correlated with both worse local control [HR 1.017 (95% CI 1.000-1.034), p = 0.047] and higher toxicity [HR 1.088 (95% CI 1.056-1.121), p < 0.001]. Increased distance from the isocenter was not associated with worse local failure or toxicity on multivariable analysis. In this retrospective analysis of SIMT VMAT radiosurgery using HD-120 MLC, 6-DOF couch, intrafraction surface monitoring, and 0 mm CTV/PTV margin, increased distance from the isocenter did not adversely impact short term local tumor control or increase high-grade toxicity. These findings are currently being tested in a prospective randomized trial.