Equivalent Patient-Reported Outcomes for Suture Staple Technique Versus Control Side-To-Side Endoscopic Gluteus Medius Repair.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 42421599.
- Also identified by DOI 10.1002/arj.70434.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare outcomes of endoscopic gluteus medius repair using the suture staple technique versus a control side-to-side repair at ≥24-month follow-up. A retrospective, single-center study from January 2015 to December 2021 was conducted with data collected during a transitional period where evolving surgical practices led to the adoption of the suture staple technique. Included were all patients with ≥2 years of follow-up and ≥6 months of well-structured nonoperative treatment. Outcomes were assessed using the modified Harris Hip Score, Victorian Institute of Sport Assessment - Gluteal, and visual analog scale. Statistical analyses included Student's t-test and Wilcoxon test for comparing group differences, with significance set at P < .05. Sixty-one patients were analyzed (control n = 31; suture staple n = 30). The overall mean age was 65.7 (standard deviation [SD] = 10.4 years); control (65.2 SD = 10.7 years), and suture stable group (66.1, SD 10.3 years). The cohort was predominantly female (78.7%), including 80.6% women in the control group and 76.7% in the suture stable group. Follow-up averaged 72.7 months (SD 34.4; range 24-142). Follow-up was significantly longer in the control side-to-side group than in the suture staple group (mean 82.8 SD 31.6 vs 62.3 SD 34.6 months; P = .0180). The modified Harris Hip Score increased from 32.7 (SD 19.1) preoperatively to 71.0 (SD 18.2) postoperatively, with no significant difference between groups (P = .5322). Victorian Institute of Sport Assessment - Gluteal improved by 40.2 units (SD 22.6), with 85.2% achieving the minimal clinically important difference of 11.3 (P = .4635). Visual analog scale scores decreased from 7.7 (SD 2.1) to 2.7 (SD 2.0), with 90.2% achieving the minimal clinically important difference of 1.3 with no significant difference (P = .1058). Sex-disaggregated analyses revealed no significant between-technique differences in men or women for modified Harris Hip Score, Victorian Institute of Sport Assessment - Gluteal, or visual analog scale (men: P = .9318, .4400, and .4276; women: P = .4288, .7501, and .2101, respectively). Both techniques provided comparable functional and pain relief outcomes. The suture staple technique and side-to-side technique are effective for endoscopic gluteus medius tendon repair, achieving significant functional and pain score improvements over a mean follow-up of 6 years. Level III, retrospective comparative cohort.