Mid-term clinical and radiographic outcomes at minimum five-year follow-up after stemless reverse shoulder arthroplasty.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 42570130.
- Also identified by DOI 10.1007/s00590-026-04880-1.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Stemless reverse total shoulder arthroplasty (rTSA) was developed to preserve humeral bone stock and facilitate revision surgery. While short-term outcomes are promising, mid-term data beyond five years remain limited. The purpose of this study was to evaluate clinical and radiographic outcomes at a minimum follow-up of five years after implantation of a stemless reverse shoulder prosthesis. We hypothesized that metaphyseal fixation would demonstrate sustained clinical function and stable radiographic integration at mid-term follow-up. This retrospective case series included 44 consecutive patients who underwent stemless rTSA. At minimum five-year follow-up, 35 patients were available for clinical and radiographic evaluation (follow-up rate 79.5%). Clinical assessment included the Constant Score (CS), age-adjusted Constant Score, American Shoulder and Elbow Surgeons (ASES) score, Simple Shoulder Test (SST), and Visual Analog Scale (VAS) for pain. Radiographic evaluation was performed using standardized two-plane radiographs and assessed for humeral and glenoid radiolucency, implant subsidence, loosening, and scapular notching. At a median follow-up of 69 months, patients demonstrated sustained functional outcomes with a median Constant Score of 74 (IQR 71-78), ASES score of 85 (IQR 80-95), SST score of 9.1 ± 2.0, and VAS pain score of 1 (IQR 0-2). The absolute Constant Score decreased slightly between the two- and five-year follow-up; however, this difference was not statistically significant (p = 0.264). Incomplete humeral radiolucent lines < 1 mm were observed in 3 patients (10.7%) and glenoid radiolucent lines in 2 patients (7.1%). No progressive loosening or implant migration was detected. Stemless reverse shoulder arthroplasty demonstrated favorable clinical outcomes and stable radiographic metaphyseal fixation at a minimum follow-up of five years. No progressive radiographic changes or implant-related complications were observed beyond the initial two postoperative years. While these findings support the mid-term performance of this implant concept, further studies with larger patient cohorts are warranted to confirm these results. IV.
Medical subject headings
- Arthroplasty, Replacement, Shoulder
- Shoulder Prosthesis
- Shoulder Joint