Data-centric, robust, and explainable multimodal deep learning for clinical decision support: A systematic review.
systematic_review · Level I
Where this comes from
- Record sourced from PubMed, PMID 42667902.
- Also identified by DOI 10.1016/j.ijmedinf.2026.106684.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Multimodal deep learning is increasingly proposed for clinical decision support (CDS) under a "data-centric" framing that prioritizes label quality, missing-modality robustness, distribution shift, calibration, and explainability. Prior reviews have examined multimodal medical AI, CDS, and data-centric methods separately, but none address their intersection. We mapped the modalities, fusion strategies, and data-centric and explainability techniques used in this recent literature, quantified how often each is implemented rather than merely mentioned, assessed deployment-relevant evidence (external validation, clinical-outcome measurement, equity), and formally appraised study-level risk of bias. Following the PRISMA 2020 statement (PROSPERO CRD420261427815; registered retrospectively), we screened 150 records and included primary, clinical, multimodal studies that applied machine or deep learning to a decision-support task and reported at least one quantitative result. Two reviewers screened and extracted data with consensus adjudication. Each study was coded against pre-specified operational definitions, separating implemented or empirically evaluated techniques from those only mentioned. Study-level risk of bias was assessed with PROBAST + AI. Synthesis was narrative. Thirty-one studies met inclusion; 30 (97%) were published between 2024 and 2026, with a median of three modalities (range 2-6), most commonly structured EHR (71%) and imaging (39%). Data-centric techniques were frequently reported (74-84% across label-noise, distribution-shift, calibration, missing-modality and class-imbalance handling; equity 61%). However, external validation was reported in only 4/31 studies (13%), a clinical or provider outcome in 3/31 (10%), and no study reported routine deployment. Overall risk of bias was high in 27/31 studies (87%), driven by the analysis domain. Within this recent, self-selected slice of the field, technical robustness and explainability techniques are widely reported but rarely validated out-of-distribution or against clinical outcomes, and the underlying evidence is at high risk of bias. Progress requires external multi-site validation, clinical-outcome measurement, formal bias appraisal, and adherence to AI reporting standards (e.g., TRIPOD + AI) before deployment can be justified.