A cadaver study appraising accuracy of blind placement of percutaneous tracheostomy.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 7485875.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
An attempt was made to place a percutaneous catheter between the first and second cartilaginous rings of the trachea in 20 cadavers presenting for postmortem examination. Only nine of the catheters entered the trachea in the intended space. All catheters which were noted to be difficult to place entered the trachea higher than intended. One third of all catheters punctured the thyroid isthmus.
Medical subject headings
- Catheterization, Peripheral