Compaction assay: a rapid and simple in vitro method to assess the responsiveness of a biopolymer matrix to enzymatic modification.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 7492720.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A rapid and simple in vitro method is described which measures the extent of unrecoiled solids compression when a complex biopolymer is subjected to a centrifugal force. This method, termed the compaction assay, was used to assess the response of purulent cystic fibrosis (CF) sputum samples to the addition of recombinant human deoxyribonuclease I (rhDNase). Enzyme treatment resulted in a dramatic decrease in DNA size, a redistribution of total DNA content from the pellet to supernatant, a significant decrease in that pellet volume and a decrease in elastic modulus. Sample elasticity, measured by a dynamic cone and plate viscometer, could be related to compaction assay results. These results suggest that the compaction assay may be a useful in vitro method for rapidly assessing the actions of enzymatic disruption of a complex biopolymer, such as that observed for the actions of rhDNase on purulent airway secretions.
Medical subject headings
- Cystic Fibrosis
- Deoxyribonuclease I