Targeting of liver metastases of colorectal cancer with IgG, F(ab')2, and Fab' anti-carcinoembryonic antigen antibodies labeled with 99mTc: the role of metabolism and kinetics.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 7493346.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to investigate targeting of the liver metastases by directly 99mTc-labeled complete (IgG) and fragmented antibodies [F(ab')2 and Fab'] in relation to their kinetics and metabolic fate. A total of 127 patients with metastatic colorectal cancer were examined [IgG1, BW 431/26 (Behringwerke, Marburg, Germany) n = 50; F(ab')2, F023C5 (Sorin Biomedica, Saluggia, Italy) n = 58; Fab', IMMU-4 (Immunomedics, Morris Plains, NJ) n = 19]. Native monoclonal antibodies (MAbs), serum samples from 10 min to 24 h postinjection (p.i.), and urine were analyzed by gel filtration chromatography. Kinetic data were deduced from whole-body and single-photon emission computed tomographic scans, performed 10 min to 24 h p.i. (region-of-interest technique). In BW 431/26, 96% of injected activity was labeled IgG1; in F023C5, 29% was F(ab')2, and 71% was Fab'; and in IMMU-4, 92% was Fab', and 8% was F(ab')2. Serum half-lives were: IgG1, 36 h (liver uptake predominant); F(ab')2, 16 h; and Fab', 4 h (renal uptake predominant). All MAbs were metabolized, fragments more rapidly than IgG, to low-molecular-weight products and excreted into the urine (e.g., Tc-cystine). In targeting liver metastases, sensitivities were found to be higher for fragments (44.1, 72.5, and 80% for BW 431/26, F023C5, and IMMU-4, respectively) but at significantly lower tumor:background ratios than with IgG (1.78 +/- 0.29 versus 1.29 +/- 0.11 and 1.43 +/- 0.53; P < 0.01). With IgG, there was a continuous tumor uptake over 24 h, whereas with fragments, the maximal uptake occurred mostly within 1 h, with subsequent clearance being slower for antigen-bound activity than for nonspecific background. Hence, diagnosis was possible mostly after 4 h with fragments but often not before 24 h with IgG. These results show that the higher sensitivity of fragments in liver lesion targeting at earlier p.i. times does not rely on an increased antibody uptake but on a more rapid clearance of nonspecific background activity due to faster metabolism and excretion. Intact MAbs show a slow, continuous uptake, leading to higher tumor:background ratios at later p.i. times, often beyond the imaging possibilities of 99mTc.
Medical subject headings
- Colorectal Neoplasms
- Immunoglobulin Fab Fragments
- Immunoglobulin G
- Liver Neoplasms
- Radioimmunodetection
- Technetium