Blunt traumatic aortic rupture: detection with helical CT of the chest.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 7568809.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine the effectiveness of helical computed tomography (CT) as a screening device to detect traumatic aortic rupture. Helical CT was used to examine 1,518 patients with nontrivial blunt trauma. Of these patients, 127 (8.37%) with abnormal CT scans of the mediastinum or aorta underwent thoracic aortography--89 patients solely for evaluation of mediastinal hematoma depicted at CT. Imaging abnormalities were correlated with surgical or clinical outcome. Twenty-one aortic injuries were identified that ranged from subtle intimal flaps to complete aortic disruption. Helical CT was more sensitive than aortography (100% versus 94.4%, respectively) but less specific (81.7% versus 96.3%, respectively) in detection of aortic injuries in patients who underwent both examinations. The association between CT findings and outcome was phi = 0.62 (chi2 = 49.1, 1 df, P < .01) and between aortography and outcome was phi = 0.85 (chi2 = 92.2, 1 df, P < .001). The P value of the difference between the phi coefficients was .10. Helical CT of the chest is effective for screening critically injured patients with possible blunt thoracic aortic injuries.
Medical subject headings
- Aortic Rupture
- Tomography, X-Ray Computed