Percutaneous ultrasound-guided needle biopsy of hepatic mass lesions using a cytohistologic approach. Comparison of two needle types.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 7572820.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study compared the ability to diagnose and accurately classify hepatic mass lesions by ultrasound-guided biopsy using two different needle types: a 20 gauge needle that yielded primarily cytologic material and an 18 gauge automated core biopsy needle. Slides prepared from each of the needle types were separately evaluated in a blinded fashion. The 20 gauge needle had a sensitivity of 90%, a specificity of 90%, and enabled exact tumor classification in 70% of cases. The 18 gauge core biopsy had a sensitivity of 85%, a specificity of 100%, and allowed exact tumor typing in 82% of cases. The sensitivity and specificity of both needle types combined was 98% and 100%, respectively, and all malignancies were correctly typed. A combined cytohistologic approach provides a highly accurate means of diagnosing and typing hepatic tumors and provides a suitable sample for confirmatory stains. Accurate tumor typing may affect therapeutic decisions.
Medical subject headings
- Biopsy, Needle
- Liver Diseases
- Needles