Comparative biomechanical stability of titanium bone fixation systems in metacarpal fractures.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 7574288.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The biomechanical properties of apex bending and torsional rigidity of 11 different titanium mini- and microplates (Leibinger and Synthes) were examined to evaluate the effects of plate design and thickness and screw size and design. Two hundred sixteen fresh-frozen human cadaveric metacarpal bones underwent a midshaft transverse osteotomy followed by application of one of the following plates: Synthes 1.5-mm and 2.0-mm five-hole linear plates; Leibinger linear 1.2-mm 5-hole, 1.7-mm 4-hole, 2.3-mm 4-hole plates; or Leibinger three-dimensional 1.2-mm 4-hole, 1.2-mm 8-hole, 1.7-mm 4-hole, 1.7-mm 8-hole, 2.3-mm 4-hole, and 2.3-mm 8-hole plates. The specimens were subjected to a three-point bending test with apex dorsal or apex volar loading or torsional loading. Analysis of variance statistical analysis revealed that increasing plate thickness and, more significantly, three-dimensional design were associated with increased rigidity.
Medical subject headings
- Bone Plates
- Bone Screws
- Fracture Fixation, Internal
- Fractures, Bone
- Hand Injuries
- Metacarpus
- Titanium