Intra-abdominal pressure measurement using a modified nasogastric tube: description and validation of a new technique.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 7706574.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study assessed the accuracy of an intragastric method of measuring intra-abdominal pressure (IAP). Prospective sequential study with simultaneous paired measurement of gastric and urinary bladder pressures. Operating theatre, University Teaching Hospital. 9 patients undergoing laparoscopic cholecystectomy were studied. Intraperitoneal pressures were monitored during peritoneal insufflation at laparoscopy up to a pressure of 20 mmHg. Intra-abdominal pressure measurements were recorded simultaneously using a gastric balloon and urinary catheter. Gastric pressure may be up to 4 mmHg higher or 3 mmHg lower than urinary bladder pressure. Intra-abdominal pressure can be measured easily in this new fashion, allowing a continuous pressure trend to be obtained without interfering with urinary output estimation.
Medical subject headings
- Abdomen
- Intubation, Gastrointestinal
- Manometry
- Pressure