Intra-abdominal pressure measurement using a modified nasogastric tube: description and validation of a new technique.

Sugrue, M; Buist, M D; Lee, A; Sanchez, D J; Hillman, K M · Intensive Care Med · 1994

prospective_cohort · Level II

Where this comes from

Abstract

This study assessed the accuracy of an intragastric method of measuring intra-abdominal pressure (IAP). Prospective sequential study with simultaneous paired measurement of gastric and urinary bladder pressures. Operating theatre, University Teaching Hospital. 9 patients undergoing laparoscopic cholecystectomy were studied. Intraperitoneal pressures were monitored during peritoneal insufflation at laparoscopy up to a pressure of 20 mmHg. Intra-abdominal pressure measurements were recorded simultaneously using a gastric balloon and urinary catheter. Gastric pressure may be up to 4 mmHg higher or 3 mmHg lower than urinary bladder pressure. Intra-abdominal pressure can be measured easily in this new fashion, allowing a continuous pressure trend to be obtained without interfering with urinary output estimation.

Medical subject headings