Long-term histological evaluation of hydroxyapatite ceramics in humans.

Oguchi, H; Ishikawa, K; Mizoue, K; Seto, K; Eguchi, G · Biomaterials · 1995

case_series · Level IV

Where this comes from

Abstract

We have investigated the interface between bone and hydroxyapatite (HA) chronically implanted in man. By light microscopy, HA appeared to bind directly to bone without intervening fibrous tissue. By transmission electron microscopy, two patterns were noted: (1) HA either bound directly to bone; or (2) electron-dense material intervened between HA and bone. The orientation of bone collagen fibres likewise showed two patterns: (1) collagen fibres were oriented parallel to the HA; or (2) the fibres were aligned perpendicularly. We have observed similar binding properties of HA to the jaw bone of humans in vivo and in vitro.

Medical subject headings