Computed tomography scans of the dens were performed on patients who had no atlantoaxial pathology. To determine whether one or two screws is optimal for fracture fixation and whether two screws can always negotiate the intramedullary odontoid cavity. Fixation of Type II dens fractures traditionally has used C1-C2 posterior wiring and fusion. Two screws placed across an odontoid fracture as a method of rigid internal fixation also has been described. However, it is not known whether two screws can always negotiate the odontoid canal. Ninety-two consecutive computerized tomography scans of the dens were performed on adults who had no atlantoaxial pathology. Measurements were taken from the scan and compared with the cross-sectional diameter of two odontoid screws. The critical diameter for the placement of two 3.5-mm cortical screws with tapping was 9.0 mm. This dimension was present in 95% of the patients studied. Correct orientation of the computerized tomography scanner is critical for accurate measurements. Two 3.5-mm screws can be used in internal fixation of Type II dens fractures in 95% of the patients if the inner cortex is tapped.