Antagonism of pancuronium- and pipecuronium-induced neuromuscular block.

Gyermek, L; Cantley, E M; Lee, C · Br J Anaesth · 1995

rct · Level II

Where this comes from

Abstract

We have compared the antagonism of neuromuscular block produced by pipecuronium with pancuronium in 80 anaesthetized surgical patients using mechanomyography and electromyography. Pancuronium 0.1 mg kg-1 or pipecuronium 0.07 mg kg-1 was given after induction of anaesthesia and neuromuscular block was adjusted to 75% twitch depression at the time of antagonism. The following regimens were used: edrophonium 0.5 and 1.0 mg kg-1, neostigmine 0.04 mg kg-1, pyridostigmine 0.3 mg kg-1 and edrophonium 0.25 mg kg-1 with pyridostigmine 0.15 mg kg-1. Antagonism was evaluated also by the head lift test. There was no difference between the reversibility of neuromuscular block produced by pancuronium or pipecuronium. Edrophonium produced a significantly faster antagonism than neostigmine or pyridostigmine but onset of action was not significantly faster than that of edrophonium with pyridostigmine. All regimens produced 100% (or near 100%) antagonism of twitch response within 15 min. However, TOF fade antagonism was more complete with pyridostigmine, neostigmine and edrophonium 1.0 mg kg-1 than with edrophonium 0.5 mg kg-1. The head lift test indicated somewhat less antagonism with edrophonium 0.5 and 1.0 mg kg-1. Using five monitoring methods, the rank order of reversal potency was: pyridostigmine approximately neostigmine > edrophonium 1.0 mg kg-1 > edrophonium+pyridostigmine > edrophonium 0.5 mg kg-1.