Closed traumatic rupture of finger flexor pulleys.

Bowers, W H; Kuzma, G R; Bynum, D K · J Hand Surg Am · 1994

case_series · Level IV

Where this comes from

Abstract

Nine patients are described with closed traumatic rupture of the digital flexor pulley system. All presented with significant flexion contractures of the proximal interphalangeal joint and bow-stringing of the flexor tendons. In seven patients, the pathology was verified at surgery and pulley reconstruction provided a good result. The diagnoses in the other patients, treated conservatively, were verified by tenogram and magnetic resonance imaging.