Venous stenosis and occlusion in hemodialysis shunts: follow-up results of stent placement in 65 patients.

Vorwerk, D; Guenther, R W; Mann, H; Bohndorf, K; Keulers, P; Alzen, G; Sohn, M; Kistler, D · Radiology · 1995

case_series · Level IV

Where this comes from

Abstract

To provide follow-up data on the use of self-expanding stents in hemodialysis fistulas to improve the technical success of balloon angioplasty. Ninety-two self-expanding vascular stents were placed in 65 patients (29 men and 36 women 25-79 years of age; mean, 57.6 years) with failing hemodialysis fistulas or shunts. Stent placement was successful in all patients, but rethrombosis of the shunt occurred in six patients (10%) within 1 week. There were 96 episodes of reobstruction. In 87 cases, percutaneous or combined surgical and percutaneous repeat intervention was performed. The cumulative shunt function rate was 88% after 6 months, 86% after 1 year, and 77% after 2 years. Stent placement in hemodialysis fistulas helps treat lesions that cannot be adequately treated with percutaneous transluminal angioplasty (PTA) alone but has a follow-up patency rate similar to that of PTA. Standard central venous stents have a better patency rate than after PTA.

Medical subject headings