Cell damage in vitro following direct contact with fine particles of titanium, titanium alloy and cobalt-chrome-molybdenum alloy.

Evans, E J · Biomaterials · 1994

basic_science · Level V

Where this comes from

Abstract

Fibroblastic cells in vitro were exposed to powders of titanium, titanium-aluminium-vanadium alloy and cobalt-chrome-molybdenum (Co-Cr-Mo) alloy, either in direct contact with the cells or separated from the cells by a microporous membrane. Fine particles of all the materials reduced cell growth when in direct contact with cells, but only the finest particles of Co-Cr-Mo alloy caused cell damage through the microporous membrane. This provides further evidence that there is a mechanism of cell damage in vitro which depends on a direct interaction between cells and particles and is largely independent of the chemical nature of the particle.

Medical subject headings