Prostate carcinoma: assessment of diagnostic criteria for capsular penetration on endorectal coil MR images.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 7972739.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To assess the accuracy of using several criteria to evaluate endorectal coil magnetic resonance (MR) images for penetration of the prostatic capsule. Thirty patients with prostate carcinoma underwent MR imaging and prostatectomy. Specified sites of potential capsular penetration on MR images were blindly evaluated by three readers for six diagnostic criteria. These evaluations were compared with pathologic findings of capsular penetration and were analyzed by means of receiver operating characteristic (ROC) analysis. The area under the ROC curve (Az) for the readers' overall impression of capsular penetration varied from .72 to .77. Highest mean Az's were for the criteria of capsular thickening (.74) and nodular extracapsular tumor (.72), although the latter finding had poor sensitivity (15%). Interobserver variation was low for all findings. Sensitivity and specificity were generally low for the diagnostic criteria. The usefulness of endorectal coil MR imaging in staging prostate cancer may be limited by the lack of diagnostic signs that uniformly identify extracapsular penetration.
Medical subject headings
- Magnetic Resonance Imaging
- Prostatic Neoplasms