A comparison of Plasmalyte 148 and 0.9% saline for intra-operative fluid replacement.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 7978133.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Thirty patients undergoing major hepatobiliary or pancreatic surgery were randomly allocated to receive either 0.9% saline or Plasmalyte 148 (a balanced salt solution), at 15 ml.kg-1.h-1. Arterial blood gas analysis was performed before and after surgery. Plasma biochemistry (Na+, K+, Cl-, lactate) measurements were made before and after surgery and at 24 h after surgery. The patients receiving 0.9% saline had significantly increased chloride concentrations (p < 0.01), decreased standard bicarbonate concentrations (p < 0.01) and increased base deficit (p < 0.01) compared to those receiving Plasmalyte 148. There were no significant changes in plasma sodium or potassium or blood lactate concentrations in either group. The exclusive use of 0.9% saline intra-operatively can produce a temporary hyperchloraemic acidosis which could be given false pathological significance. In addition it may exacerbate an acidosis resulting from an actual pathological state. The use of a balanced salt solution such as Plasmalyte 148 may avoid these complications.