Why monitor peak vancomycin concentrations?
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 7997005.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Peak and trough serum concentrations are routinely measured to monitor vancomycin therapy. Optimal therapy depends upon maintaining a concentration above that necessary for antibacterial activity and is therefore determined by the trough concentration. I determined the post dose increases in serum drug concentrations in routine clinical practice in adult patients without renal failure. Mean increases of 16.6 mg/L (SD 6.1) (peak samples collected 1 h post infusion) were measured from 165 paired samples. The results suggest that as long as trough concentrations do not exceed 15 mg/L, peak levels will not exceed normally accepted safe concentrations, and therefore do not need to be measured.
Medical subject headings
- Drug Monitoring
- Vancomycin