Helical CT during arterial portography: optimization of contrast enhancement and scanning parameters.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 7997587.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine the optimal scanning parameters for helical computed tomography during arterial portography (CTAP) of the liver. Single- and double-helix CTAP were performed in 11 and 20 adult patients, respectively, with 200 mL of contrast material (300 mg of iodine per milliliter) injected at a rate of 3 mL/sec via the superior mesenteric artery. Scanning delays were adjusted for single-helix CTAP so the last scan was obtained at 66 seconds. Delays were adjusted for double-helix CTAP so the last scan during the first helix (CTAP-1) was obtained 10 seconds before the end of the injection at 56 seconds and the first scan during the second helix (CTAP-2) was obtained at the end of the injection at 66 seconds. Single-helix CTAP scans were of poor quality owing to multiple perfusion abnormalities. Lesion detection for double-helix CTAP-1 was 93.2% and was 100% for CTAP-2, and CTAP-2 scans had significantly fewer perfusion abnormalities. A scanning delay of 60-66 seconds appears to be optimal. The CTAP-1 scans showed no useful information and need not be acquired.
Medical subject headings
- Carcinoma, Hepatocellular
- Liver
- Liver Neoplasms
- Portography
- Tomography, X-Ray Computed