Comparison of aural infrared with traditional rectal temperatures in children from birth to age three years.

Petersen-Smith, A; Barber, N; Coody, D K; West, M S; Yetman, R J · J Pediatr · 1994

cross_sectional · Level IV

Where this comes from

Abstract

Glass-mercury rectal temperatures were compared with aural temperatures ("rectal equivalent" mode) in 234 children from birth to age 36 months. Sixty-two percent of measurements were divergent by at least 0.3 degrees C, 35% by greater than 0.6 degrees C. The aural infrared thermometer cannot be recommended for these ages; measurements were unacceptably inaccurate.

Medical subject headings