A randomised trial of patient repositioning during radiotherapy using a megavoltage imaging system.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 8066195.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Effectiveness of radiotherapy is dependent on the accuracy of beam alignment. Recent developments in megavoltage imaging allow real-time monitoring of beam placement. Maximum gains from this new technology can only be made if the information is utilised to correct patient positioning prospectively before the majority of a treatment fraction is delivered. We have developed and utilised an integrated megavoltage imaging system to perform a randomised trial demonstrating significant improvements in accuracy using treatment intervention techniques for pelvic radiotherapy. The mean field-placement accuracy improved from 4.3 mm to 2 mm and the proportion of treatments given with a field-placement error of > or = 5 mm decreased from 69% to 7%. This improvement in accuracy may enable smaller margins around the target volume to be chosen whilst ensuring complete target coverage at each treatment fraction.
Medical subject headings
- Prostatic Neoplasms
- Radiotherapy Planning, Computer-Assisted
- Urinary Bladder Neoplasms