Fixation with biodegradable devices of acetabular components in a canine model.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 8070204.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Cementless total hip arthroplasty was performed in 13 dogs. The acetabular component was anchored with two biodegradable devices (polylactic acid) in seven dogs and with two titanium screws in six dogs. At 14 weeks, histomorphometric determinations of bony ingrowth into the porous coating of the acetabular weight bearing dome was 54.4% when fixed with the biodegradable devices and 58.9% when fixed with the titanium screws (no statistically significant difference; p = 0.556). At the sites of fixation, less bony ingrowth occurred with the biodegradable devices. The use of biodegradable devices in total hip arthroplasty should overcome the potential metal corrosion of titanium screws that can lead to polyethylene wear.
Medical subject headings
- Biocompatible Materials
- Hip Prosthesis
- Lactates
- Lactic Acid
- Orthopedic Fixation Devices
- Polymers
Anatomy
- hip
- pelvis