Venoatrial pathways after the Mustard operation for transposition of the great arteries: anatomic and functional MR imaging.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8090893.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate spin-echo (SE) and cine gradient-echo (GRE) magnetic resonance (MR) imaging with velocity mapping for detecting late complications of the Mustard operation. Twenty-one patients were studied with MR imaging 1-22 years after undergoing the Mustard operation. Twenty were also studied with transthoracic echocardiography, 18 with angiocardiography, and five with transesophageal echocardiography. MR imaging showed no venoatrial obstruction in nine patients. This result was confirmed with angiocardiography in seven cases and postmortem examination in one case. In one case, MR imaging demonstrated a leak at the baffle suture line. Of 12 cases with venoatrial obstruction at MR imaging, nine were confirmed with angiocardiography or surgery. There were two false-positive MR studies and one case in which no conclusion was reached. With addition of cine GRE sequences and velocity mapping to SE sequences, MR imaging is a useful noninvasive method of investigating late complications of the Mustard operation.
Medical subject headings
- Magnetic Resonance Imaging
- Postoperative Complications
- Transposition of Great Vessels