"Crisscross" MR imaging: improved resolution by averaging signals with swapped phase-encoding axes.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 8090908.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
At conventional magnetic resonance imaging, the number of phase-encoding steps is often chosen to be less than the number of readout samples, resulting in reduced spatial resolution in the phase-encoding direction. Signal averaging improves the signal-to-noise ratio of the image but does not affect this asymmetry in resolution. By swapping the phase- and frequency-encoding directions between excitations and averaging the resultant data sets ("crisscross" imaging), equal spatial resolution can be obtained in both principal directions. Increased spatial resolution can be obtained with this method with no increase in imaging time, and the method can potentially be applied in echo-planar and three-dimensional Fourier transform imaging.
Medical subject headings
- Brain
- Image Processing, Computer-Assisted
- Magnetic Resonance Imaging
- Signal Processing, Computer-Assisted