Occupational asthma due to indirect exposure to lauryl dimethyl benzyl ammonium chloride used in a floor cleaner.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 8091336.
- Also identified by PMC identifier 475138.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The case is described of a 44 year old pharmacist who developed severe occupational asthma threatening his continued employment, confirmed by serial measurement of peak expiratory flow at home and work. The cause was found to be the cleaning agent used in his office when it was unoccupied. Bronchial challenge testing identified the specific agent to which he was sensitised as lauryl dimethyl benzyl ammonium chloride, a constituent of the floor cleaner. Substitution of this floor cleaner by a simple detergent cleaner led to a substantial improvement in his asthma, confirmed by repeated serial peak flow measurements.
Medical subject headings
- Anti-Infective Agents
- Asthma
- Benzalkonium Compounds
- Household Products
- Occupational Diseases
- Pharmacists