Use of a more physiologic oral glucose solution during screening for gestational diabetes mellitus.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 8092215.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We sought to compare in pregnant women deviations in glucose values, insulin values, and the occurrence of side effects between a "standard" 50 gm oral glucose solution (50 gm of glucose in 150 ml of fluid, 1.85 mol/L) versus a modified "physiologic" 50 gm oral glucose solution (50 gm of glucose in 450 ml of fluid, 0.62 mol/L) as a screening test for gestational diabetes mellitus. A total of 132 pregnant women underwent (1) a standard 50 gm, 1-hour oral glucose screening test, (2) a 50 gm, 1-hour oral glucose screening test using the modified solution, and (3) a 3-hour oral glucose tolerance test (with 100 gm of glucose in 300 ml of fluid, 1.85 mol/L). Compared with the "standard" regimen, both glucose and insulin values were significantly higher in the "modified" regimen 30 minutes after ingestion, indicating a more rapid absorption of glucose. Nausea and vomiting were greatly decreased with the modified glucose solution. The 1-hour glucose values were not statistically different. A more dilute, more palatable oral glucose solution can be used to screen for gestational diabetes mellitus, yielding more accurate results and eliminating unpleasant side effects.
Medical subject headings
- Diabetes, Gestational
- Glucose
- Glucose Tolerance Test
- Mass Screening