Effect of external hip protectors on hip fractures.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 8093267.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Most hip fractures seem to be related to trauma near the hip, so a controlled trial was conducted to investigate the effect of external hip protectors on the prevention of such fractures in residents of a nursing home. 10 of the 28 wards in the nursing home were randomised to receive external hip protectors; thus 167 women and 80 men were given protectors and 277 and 141 men no protectors. A fall register was set up for 2 treatment wards (45 residents) and 2 control wards (76 residents). There were 8 hip and 15 non-hip fractures in the hip-protector group and 31 hip and 27 non-hip fractures in the control group. The relative risk of hip fractures among women and men in the intervention group was 0.44 (95% CI 0.21-0.94). None of the 8 residents in the intervention group who had a hip fracture was wearing the device at the time of the fracture. 154 falls were registered and 20% of these falls produced a direct impact to the hip. In 25 falls direct impact to the hip was sustained at a time when hip protectors were not being worn, and 6 fractures were produced. The study indicates that external hip protectors can prevent hip fractures in nursing-home residents.