Diamorphine-bupivacaine mixture compared with plain bupivacaine for analgesia.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 8110553.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We have studied the efficacy of two extradural infusions (10 ml h-1) in 50 patients in active labour. Patients in the diamorphine group (n = 25) received 0.0625% plain bupivacaine 6.25 mg h-1 mixed with 0.005% diamorphine 0.5 mg h-1 and those in the control group (n = 25) received 0.125% plain bupivacaine 12.5 mg h-1. Both groups received intermittent "top-ups" of 0.25% bupivacaine 10 ml when indicated. Although median pain scores during the infusion were similar in both groups, patients in the diamorphine group indicated greater satisfaction with the infusion (88% very satisfied, compared with 52% in the control group (P < 0.02)). There were no differences in the incidence of hypotension, instrumental vaginal delivery, number of "top-ups", duration of the second stage or extent of motor block. However, patients in the diamorphine group had a high incidence of pruritus (44%, compared with 0% in the control group (P < 0.01)).
Medical subject headings
- Analgesia, Epidural
- Analgesia, Obstetrical
- Bupivacaine
- Heroin