Double sequential external shocks for refractory ventricular fibrillation.

Hoch, D H; Batsford, W P; Greenberg, S M; McPherson, C M; Rosenfeld, L E; Marieb, M; Levine, J H · J Am Coll Cardiol · 1994

case_series · Level IV

Where this comes from

Abstract

A technique for terminating refractory ventricular fibrillation is described. Refractory ventricular fibrillation can occur in up to 0.1% of electrophysiologic studies. Animal studies have shown that rapid sequential shocks may reduce ventricular fibrillation threshold. Five patients of 2,990 consecutive patients in a 3-year period experienced refractory ventricular fibrillation during 5,450 routine electrophysiologic studies. Multiple shocks were delivered by means of a single defibrillator. Double sequential shocks were delivered externally 0.5 to 4.5 s apart by means of two defibrillators with separate pairs of electrodes. In all patients, standard defibrillation was unsuccessful, but all were successfully resuscitated using the double sequential shocks. This report stresses the importance of an additional defibrillator being readily available during electrophysiologic testing. This technique of rapid, double sequential external shocks may have general applicability, providing a simple and potentially lifesaving approach to refractory ventricular fibrillation.