Comparison of technetium-99m-Q3 and thallium-201 for detection of coronary artery disease in humans.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 8151379.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Technetium-99m-Q3 is a myocardial imaging agent that produces prompt myocardial visualization in humans. In 19 patients with angiographic coronary artery disease, 2 patients with no angiographic coronary artery stenosis greater than 50% of the luminal diameter and 6 healthy volunteers, exercise and resting myocardial imaging were performed with 99mTc-Q3 and also with 201Tl. Technetium-99m-Q3 imaging began 15 min after injection at rest and with exercise, in a complete imaging sequence that required less than 100 min. Overall accuracy for coronary disease detection was 78% (21 true-positive or true-negative studies among 27 study participants) by tomographic thallium imaging versus 89% for 99mTc-Q3 tomographic imaging (p = ns). Accuracy for detection of individual coronary stenoses was 75% (61 true-positive or true-negative coronary segment classifications among 81 total coronary segments) for 201Tl imaging and 83% for 99mTc-Q3 imaging (p = ns). Technetium-99m-Q3 when used in a rest-exercise sequence that can be completed in 100 min appears to provide comparable diagnostic accuracy to 201Tl for overall coronary disease detection and detection of individual coronary artery stenoses.
Medical subject headings
- Coronary Disease
- Organotechnetium Compounds
- Phosphines
- Thallium Radioisotopes