Aortic dissection caused by angiographic procedures.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 8153323.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To describe findings in, and the clinical course and outcome of, aortic dissection (dissecting aneurysm) caused by angiographic procedures. The records of approximately 15,500 angiographic procedures performed between 1985 and 1991 were reviewed. In the six cases of iatrogenic aortic dissection identified, computed tomography (CT) was performed for diagnosis, follow-up, or both. The type of aortic dissection was Stanford type A in three patients and Stanford type B in three patients. The sites of injury were the abdominal aorta (n = 2), right brachiocephalic artery (n = 2), middle of the thoracic aorta (n = 1), and right common iliac artery (n = 1). One patient had anterograde dissection from the site of injury; two patients, retrograde dissection; and three patients, extensive dissection that extended in both anterograde and retrograde directions. Retrograde dissections decreased in size or disappeared in 1-3 months due to the absence of reentry, whereas anterograde dissections persisted during follow-up (15-27 months). All patient were treated without surgery. Angiographers should be aware of this potentially serious complication. The extent and type of the aortic dissection can be determined with CT.
Medical subject headings
- Aortic Dissection
- Angiography
- Aortic Aneurysm, Abdominal
- Aortic Aneurysm, Thoracic
- Iatrogenic Disease