Endoscopic carpal tunnel release: preliminary report.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8166899.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The surgical technique of endoscopic carpal tunnel release using the Concept Carpal Tunnel Relief Kit (Linvatec, Largo, FL) is described. This is a single-portal technique and can be performed with any standard (4-mm) arthroscope available in the operating room. The results of the first 100 cases treated by the author are reported. Ninety-four percent of the patients achieved relief of symptoms. No permanent neurological or vascular injury occurred in this series. The grip strength returned to preoperative level in 3-4 weeks in the majority of patients. Subjective evaluation showed a greater degree of patient satisfaction when compared with results of the open technique.
Medical subject headings
- Arthroscopes
- Carpal Tunnel Syndrome
Anatomy
- wrist
- hand