Lumbar and lumbosacral fusions using Cotrel-Dubousset pedicle screws and rods.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8178230.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The first 50 consecutive patients stabilized with Cotrel-Dubousset rods for lumbar or lumbosacral fusions were followed for an average of 2 years. The occurrence of fusion, maintenance of alignment, and rate of hardware complications were examined. There were 28 men and 22 women, ages 18-87 years, and 133 vertebral levels. Twenty-nine sets of 5-mm, and 21 pairs of 7-mm, rods were placed. Two hundred and sixty-eight pedicle screws were used. Forty-eight out of 50 (96%) patients demonstrated successful arthrodesis after their initial procedure. One pedicle screw became separated from the rod. No rods migrated or broke. Seven (2.6%) pedicle screws bent and 3 (1%) broke. Large and small diameter Cotrel-Dubousset rods allowed short segment lumbar and lumbosacral fusion with a high degree of reliability.
Medical subject headings
- Bone Nails
- Bone Screws
- Spinal Fusion
Anatomy
- lumbar spine
- sacrum-coccyx