Usefulness of transesophageal echocardiography for diagnosis of infected transvenous permanent pacemakers.

Vilacosta, I; Sarriá, C; San Román, J A; Jiménez, J; Castillo, J A; Iturralde, E; Rollán, M J; Martínez Elbal, L · Circulation · 1994

case_series · Level IV

Where this comes from

Abstract

Transesophageal echocardiography is superior to transthoracic echocardiography in detecting left-sided valvular vegetations. There are no data on the value of transesophageal echocardiography in the diagnosis of infected transvenous permanent pacemakers. Transthoracic and transesophageal echocardiography was performed in 10 patients for whom there was clinical suspicion of infected permanent transvenous pacemakers. Transthoracic echocardiography detected pacemaker lead vegetations in 2 patients, whereas transesophageal echocardiography visualized pacemaker lead vegetations in 7 patients. Surgical confirmation was obtained in 6 of these 7 patients. Most patients had more than one pacemaker electrode in place. Local complications at the generator pocket were present in 6 patients. Staphylococcus was the predominant causative organism. Transesophageal echocardiography is superior to transthoracic echocardiography in the detection of pacemaker lead vegetations.