Quantification of patient to patient variation of skin erythema developing as a response to radiotherapy.

Russell, N S; Knaken, H; Bruinvis, I A; Hart, A A; Begg, A C; Lebesque, J V · Radiother Oncol · 1994

Where this comes from

Abstract

A method is described to determine accurately skin redness during a course of radiotherapy using reflectance spectroscopy utilizing information from across the visible spectrum according to the L*a*b* color coordinate system. The method was used to quantify the development of skin erythema during and after electron beam irradiation of the chest wall following mastectomy. A number of factors were identified which could influence the wide variation in response seen between patients. These were: intra- and inter-observer variation; intra- and inter-patient variation and variation in the actual dose delivered. Statistical analysis, including an analysis of variance of inter- and intra-patient variation, revealed that the major factor that accounts for the observed difference between patients is a true inter-patient variation, with a coefficient of variation, corrected for intra-patient variation, of 43%. Within the narrow dose range administered in this study, there was no demonstrable dose-effect relationship, raising questions about the role of cell death in the basal layer of the epidermis in the pathogenesis of radiation induced erythema.

Medical subject headings