Contraction rates of meshed, nonexpanded split-thickness skin grafts versus split-thickness sheet grafts.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 8215133.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Contraction rates of wounds covered by meshed, nonexpanded split-thickness skin grafts were compared with split-thickness sheet-grafted wounds in a porcine model. No significant difference was found in wound contraction. When compared with previous studies, this study shows that differences in contraction previously observed were not a result of meshing and suggests that expansion may be the cause of the difference previously observed.
Medical subject headings
- Skin Transplantation
- Surgical Mesh